Ensures high conductivity and consistent electrical performance.
Allows organised wiring for safe multi-circuit power distribution systems.
Enables easy routing and smooth installation in confined spaces.
Supports different safety and enhanced fire-resistance requirements.
Provides strong mechanical protection and long service life performance.
Helps ensure accurate measurement and reduced material wastage.
Suitable for distributing power through multiple cores.
Ideal for organised and efficient wiring inside control panels.
Used for internal wiring requiring flexibility
Supports power distribution in offices and retail environments.
Reliable wiring for equipment and critical operational circuits.
Suitable for open and structured cable routing.
| Nominal Cross Sectional Area of Conductor |
Number / Nom. Dia of Conductor Strands |
Max Conductor Resistance per KM @ 20°C |
Nominal Thickness of Insulation |
Nominal Thickness of Sheath | Approximate Overall Diameter | 70°C PVC insulated and ST3 sheathed cables | 85°C HR PVC insulated and ST2 sheathed cables | ||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Current carrying capacity (Unenclosed - clipped directly to a surface or on cable tray) | Current carrying capacity (Unenclosed - clipped directly to a surface or on cable tray) | ||||||||||||
| 2 Core | 3 Core | 4 Core | 2 Core | 3 Core | 4 Core | 2 & 3 Core Cables for Single Phase AC/DC |
3 & 4 Core Cables for Three Phase AC |
2 & 3 Core Cables for Single Phase AC/DC |
3 & 4 Core Cables for Three Phase AC |
||||
| Sq. mm | mm | Ohms | mm | mm | mm | mm | mm | mm | mm | Amps | Amps | Amps | Amps |
| 0.50 | 16/0.2 | 39.0 | 0.6 | 0.9 | 0.9 | 0.9 | 6.2 | 6.5 | 7.0 | 4 | 4 | 5 | 5 |
| 0.75 | 24/0.2 | 26.0 | 0.6 | 0.9 | 0.9 | 0.9 | 6.5 | 6.9 | 7.5 | 7 | 7 | 8 | 8 |
| 1.0 | 32/0.2 | 19.5 | 0.6 | 0.9 | 0.9 | 0.9 | 6.9 | 7.4 | 8.0 | 12 | 10 | 14 | 12 |
| 1.5 | 30/0.25 | 13.3 | 0.6 | 0.9 | 0.9 | 1.0 | 7.5 | 8.0 | 8.7 | 16 | 14 | 19 | 17 |
| 2.5 | 48/0.25 | 7.98 | 0.7 | 1.0 | 1.0 | 1.0 | 8.9 | 9.4 | 10.3 | 20 | 18 | 24 | 22 |
| 4.0 | 56/0.3 | 4.95 | 0.8 | 1.0 | 1.0 | 1.0 | 10.1 | 10.8 | 11.9 | 27 | 24 | 32 | 29 |
| 6.0 | 84/0.3 | 3.30 | 0.8 | 1.1 | 1.2 | 1.2 | 11.5 | 12.4 | 13.6 | 34 | 30 | 41 | 36 |
| 10.0 | 80/0.4 | 1.91 | 1.0 | 1.3 | 1.4 | 1.4 | 14.7 | 15.8 | 17.5 | 44 | 39 | 53 | 47 |
| 16.0 | 126/0.4 | 1.21 | 1.0 | 1.4 | 1.4 | 1.4 | 17.0 | 18.1 | 20.0 | 61 | 55 | 73 | 66 |
| ** As per conductor class 5 of IS:8130-1984 | |||||||||||||
High-purity 99.97% copper conductors for dependable performance
Available in multiple core options for versatile applications
Strong insulation and sheath for mechanical and electrical protection
Suitable for residential, commercial, and industrial installations
Trusted quality backed by BharatBond — Bharosa Bhi, Bandhan Bhi